Touch Plate Lighting Control offers new Universal Lighting panels that work with all types of switches. NOTE: Remcon relays are no longer manufactured.ĭiscontinued Remcon Relay Upgrade and Replacement PathĪ system upgrade is required if you need to replace all of your Remcon relays because they have been discontinued. If you want to upgrade you may choose to replace the complete system with new electrical panels, relays and switches from Touch-plate Lighting Controls. Remcon made two types of relays: Remcon light relays (typically mounted in the ceiling near the light fixture and Remcon closet relays that that control a closet light by opening and closing the door, both of which were made in very old mechanical latching versions as well as newer, more-recently discontinued solid state versions. Note that any switches connected to each other or to the relays (any parts connected in any way) must all be on the same circuit/phase. If using the new Touch Plate powered relay packs to create a new standalone 2-wire system, these too must not be connected in any way with the Remcon part of your system (no shared common wires, no connection to master panels). All Remcon relays on a circuit/phase must be the same type: either old mechanical latching or new solid state they cannot be mixed on either side because of the difference in the control circuit. Also, only Remcon relays should be used with Remcon switches. Important: Do not mix & match relays the same circuit, whether solid state vs. Unfortunately, replacement LED lighted switches from other brands won't illuminate because the interaction of the newer switches and relays do not function in the same way. Pilot Light Functionality: Note that even though these old curved rocker switches were lighted when on, that pilot light functionality came from the advanced engineering of the specialized switches used in conjunction with the combination relay/transformers. (Lefthand relay in photo.) Remcon relays were typically installed near the light fixture. (Righthand relay in photo.) In contrast, the new relays are solid state units that are flat on the front and back with stepped sides and a locknut on top for mounting into a metal electrical box. Vintage Remcon relays were a mechanical latching type with a solenoid inside a cylinder on top of a square base. Remcon Difference: Remcon relays were unique in that each unit was actually a transformer with a built-in relay, unlike other low volt systems where the transformer and the relay are separate components. To accurately test your switches and relays in other areas of your home, you must disconnect each switch from the master controller panel and test just a single switch and relay attached to a light. You will want to independently check all the switches and relays to ensure that none is responsible for the lighting problem you are experiencing. Test Independently: If lights in a whole section of your home are not working, the switches in one of these controllers may have started to fail. (This is only possible if the current Remcon relays are arranged in a panel layout in one location, rather than installed remotely in each room near the light fixture.) Note that if you want the same type of functionality as a master switch in an updated system, you would need to upgrade to a Touch-Plate panel with grouping capability that could control multiple lights at one time. Note that this master control panel fit a 4-gang box. There are no switches directly wired to the master switch, and any master functionality would be lost once updating to new switches. When the master switch is pushed, a copper bar makes momentary contact with all the switches at once thereby turning all lights on (up position) or off (down position). The central switch is connected to a copper bar that runs the length of the panel. They provide master override control of lighting in eight areas such as hallways, bedrooms, and outdoors. This central override control was also a safety feature that would allow you to instantly illuminate any area of the house, for example, after hearing a window break at the far end of your home.Ĭentral Control: Each of the four switches on either side of the central master selector switch is typically connected to one or more lights in a section of your home. Pilot lighted switches illuminate when the load (light, pump, etc.) is on so you can tell if lights are left on in a far section of your home. These convenient pilot lighted controllers were often installed by the front door, back door, and/or in the master bedroom of a home. How It Works: Remcon systems have an unusual remote control master panel that allows you to turn on and off all lights from a single oversized rocker in the middle of a 9-switch panel.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |